dlc australia
products
Home Contact Us Products Links Specials Announcements Orders

Monitoring Equipment

Go to » Respalert | ECG | Pulse Oximeters

   
 

Monitoring - Pulse Oximeters

Go to » 19NT2A-V Table Top Pulse Oximeter | 19NT2C-V Vital Signs Monitor

               | Vet 420A Multiparameter Monitor | Nonin 9847V Pulse Oximeter

Solaris NT2A-V Table Top Pulse Oximeter

Code: 19NT2A-V

  • Bright, Easy-to-Read Large LED Display
  • Durable, Compact and Lightweight
  • Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
  • Accurate and Reliable During Low Perfusion and Motion
  • Audible/Visual Three Level Alarms with Adjustable Alarm Volume Control
  • 72-hour Data Memory Allowing On-screen Viewing of SpO2 and Pulse Rate Trends
  • Suitable for Equine, Dog & Cat

Performance Measurement Range
SpO2: 0%~100%

Resolution: 1%
Pulse Rate: 25bpm~400bpm
Resolution: 1bpm


SpO2 Accuracy
No Motion:          70%~100%±2%
                             0~69% unspecified
Motion:                70%~100%±3%
                             0~69% unspecified
Low Perfusion: 70~100%±3%
                             0~69% unspecified

Pulse Rate Accuracy
No Motion: ±3%
Motion: ±5%
Low Perfusion: ±5%

Displays and Indicators
SpO2, Pulse Rate and Pulse Strength Bar
Pulse Search Indicator
Low Perfusion and Motion Warning Indicator
Alarm Silence Indicator
AC Power and Battery Charge Indicator
Low Battery Warning Indicator
Sensor Disconnect and Sensor Off Warning Indicator

Alarm
Audible/Visual Alarms
Adjustable Alarm Limits

Output
RS-232 Digital Output from Serial Port
Nurse Call Function

Electrical Instrument Power Requirements:
100~240VAC,50/60Hz,20VA
Fuse Rating: 1.0 A

Battery
Internal Battery: 12V 3.6Ah
Battery Capacity: ≥24 hours

Environment
Operating Temperature: 5ºC~40ºC (41ºF~104ºF)
Operating Humidity ≤ 80%
Operating Altitude: -390m~5,000m(-1,280 ft~16,404 ft )
Transport/Storage Temperature: -20ºC~70ºC (-4ºF~158ºF)
Storage Humidity ≤ 95%

Physical Characteristics

Dimensions: 264 mm (W) x 95 mm (H) x 172 mm (D) /
10.39 in (W) x 3.74 in (H) x 6.77 in (D)
Net Weight: 2.5 kg /5.5 lb
Gross Weight: 3.5 kg/7.7 lb

...........................................................................................................................................................

Solaris NT2C-V Vital Signs Monitor

Code: 19NT2C-V

  • Bright, Easy-to-Read Large LED Display
  • Durable, Compact and Lightweight
  • Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
  • Accurate and Reliable During Low Perfusion and Motion
  • Audible/Visual Three Level Alarms with Adjustable Alarm Volume Control
  • 72-hour Data Memory Allowing On-screen Viewing of SpO2 and Pulse Rate Trends
  • Optional Internal Thermal Recorder
  • Nurse Call Network Compatibility

Performance Measurement Range
SpO2:0~100%

Resolution: 1%
Pulse Rate: 25bpm~400bpm

Resolution: 1bpm

SpO2 Accuracy
No Motion:         70~100% ±2%
                             0~69% unspecified
Motion:                70~100% ±3%
                             0~69% unspecified
Low Perfusion: 70~100% ±3%
                             0~69% unspecified

Pulse Rate Accuracy
No Motion: ±3%
With Motion: ±5%
Low Perfusion: ±5%

Non-Invasive Blood Pressure
Measurement range: 15bpm~270mmHg
Resolution: 1mmHg
Method: oscillometrie

Mode: Manual/ Automatic/ Continous


Alarm
Audible/Visual Alarms
Adjustable Alarm Limits

Temperature
Measurement range: 25~45°C
Accuracy: ±0.2°C

Output
RS-232 Serial Port for Digital Output
Nurse Call Function

Electrical Instrument
Power Requirements: 100~240VAC, 50/60Hz, 40VA
Fuse Rating: 1.0A

Battery
Internal Battery: 12V
Battery Capacity: ≥ 24 hours

Environment
Opreation Temperature: 5°C~40°C (41°F~104°F)
Humidity: 10%~95%
Transport/Storage

Temperature: -20~+70°C (-4~158°F)
Humidity: 10~95%

Physical Characteristics
Dimensions: 264mm(W) x 95mm(H) x 172mm(D)
                        [10.39in(W) x 3.74in(H) x 6.77in(D)
Net Weight: 2.25kg/5ib

Compliance
EN60601-1/ GB9706.1
EN60601-1-2, EN60601-2-49

...........................................................................................................................................................

Vet 420A Multiparameter Monitor

Code: 19VET420A

  • 7” Colour TFT Display
  • 4-Channel Waveform Display (2x ECG Channels)
  • Non-volatile memory
  • Manual / Auto / Stat Measurements of NIBP, Auto interval
    1 – 120 minutes selectable
  • Applications from small to large animals
  • Networking Capability
  • Alarm Limit Setup
  • AC / DC Operation
  • Built-in Battery
  • Digital Serial Auto-correction Technology, SAC Patented
    (Optional)

ECG

Standard 3-Lead or 5-Lead selectable

Lead Selection: I, II, III, or I, II, III, aVR, aVL, aVF, V

Lead Connection: RA, LA, RL, LL, V

Lead Fault Alarm: Audible and Visual

Sweep Speed: Adjustable

Gain Selection: Manual (5 selections), Auto

Protection: Against electrosurgical interference and Defibrillation

Pulse Oximetry (SPO2)

Display: Digital, Waveform, Pulse Rate

Probe: For small to large animals

Probe Types: Small and Large lingual probe

Non-Invasive Blood Pressure (NIBP)

Method: Automatic Oscillometric

Parameters: SYS/DIA/MAP/ Pulse Rate

Operating Modes: Manual / Auto / STAT

Scale: mmHg/kPa

Over-pressure protection: Yes

Temperature (TEMP - probe is optional)

Channel: 2 channels

Scale: Celsius / Fahrenheit

Range: 0-50°C / 32-122°F

Respiration
Impedance method
Range: 0~50bpm


Recorder (Optional)
Print Mode: Waveform and Text
Type: External Thermal Recorder, 2 channels


Power Supply
Battery: Rechargeable, built-in
AC Voltage Input: 110-230VAC, 50/60Hz


Physical Specifications:
Weight: Approximately 6.6Ibs
Dimensions: 7.1” H x 8.27” W x 4.33” D
Or 18 H x 21 W x 11 D cm

(Dimensions exclude recorder)


Safety Approval and Quality System
Safety Standard: IEC60601 serials
Quality System: ISO 9001 & EN 46001 & ISO 13485 Certified


Analysis and Storage
600– set Blood Pressure Data Storage and Recall
48 Hours Trend Information
1 minute full disclosure

Accessories

...........................................................................................................................................................

Nonin Pulse Oximetry + CO² Detector

The 9847V monitors oxygen saturation, pulse rate and end-tidal carbon dioxide in intubated animals. Other features include:

  • Veterinary-specific software (wide pulse rate range: 18-450 bpm)
  • Veterinary-specific sensors
  • Audible "breath beep"
  • Alarms for apnoea, SpO2 and pulse rate
  • Enhanced sensitivity to low perfusion signals
Specifications:  
Oxygen Saturation Range 0 to 100%
Pulse Rate Range 18 to 450 Pulses Per Minute
CO² Range 0 to >75mmHg, approximately
CO² Response Time 250 milliseconds
Breath Detection Threshold 5mmHg, approximately
Respiration Rate Range 1 to 60 Breaths Per Minute
Pulse Indicator Tricolor Pulse Quality Indicator
Digital Displays SpO² and Pulse Rate
CO² Display 8 element bar graph
Visual or Audible Indicators battery, alarm disable Breath beep (variable pitch), apnea, low battery, alarm disable
Audible Alarms Apnea, SpO² and Pulse Rate
Warranty 3 years on monitor and 6 months on cables and sensors

Sensors

2000SL
Lightweight, ultra-sensitive clip on sensor for tongue application or paw pad, and well-vascularized areas, as appropriate.

2000SA
Flexible wrap sensor for placement on toe (dog, large animal) or base of the tail (small animal).

2000T
Convenient sensor of placement on the underside, base of the tail or other well-vascularized surfaces.